New Requirements for Fire-Fighters’ Outfits
The 2014 amendments to SOLAS and the Fire Safety Systems (FSS) Code* will enter into force on 1 July, 2014, introducing revised and new requirements for fire-fighter’s outfit breathing apparatus and two-way portable radiotelephone apparatuses, as follows:
Breathing apparatus
1. Changes to SOLAS regulation II-2/10.10.1 and the FSS Code mean that: “Compressed air breathing apparatus shall be fitted with an audible alarm and a visual or other device which will alert the user before the volume of the air in the cylinder has been reduced to no less than 200 litres.”